top of page

Jazzy Select GC joysticks (1,2,3)

GC1 GC2 GC3 error flash codes

ERROR CODES

 

1 Flash The batteries need charging.

There is a bad connection to

the batteries.

Check the battery connections. If the

battery connections are good, then try

charging the batteries.

2 Flashes There is a bad connection on

the left motor.

Check the left motor connections and

wiring harnesses.

3 Flashes The left motor has a short to

the battery connection.

Contact your authorized Pride Provider.

4 Flashes There is a bad connection on

the right motor.

Check the right motor connections

and wiring harnesses.

5 Flashes The right motor has a short to a

battery connection.

Contact your authorized Pride Provider.

Scroll Left

to Right

The charge inhibit has been

activated.

Make sure that the battery charger is

not connected to the power base.

7 Flashes There is a joystick fault. Make sure the joystick is in the center

position and then power off and

on again.

8 Flashes There is a control system fault. Check power module and joystick

module connections and wiring.

9 Flashes The park brakes have a bad

connection.

Check the left and right motor connections

and wiring.

10 Flashes An excessive voltage has been

applied to the control system.

Check the battery connections.

bottom of page